Home ProductsDifferential pressure(DP) transmitter

4-20 mA differential pressure transmitter with HART protocol

Certification
Good quality Differential Pressure Capacitive Sensor for sales
Good quality Differential Pressure Capacitive Sensor for sales
I'm Online Chat Now

4-20 mA differential pressure transmitter with HART protocol

China 4-20 mA differential pressure transmitter with HART protocol supplier
4-20 mA differential pressure transmitter with HART protocol supplier 4-20 mA differential pressure transmitter with HART protocol supplier 4-20 mA differential pressure transmitter with HART protocol supplier 4-20 mA differential pressure transmitter with HART protocol supplier

Large Image :  4-20 mA differential pressure transmitter with HART protocol

Product Details:

Place of Origin: China
Brand Name: AUTO
Certification: ISO9001:2000,CE
Model Number: AT3051

Payment & Shipping Terms:

Minimum Order Quantity: 1PC
Price: $200/PC
Packaging Details: carton
Delivery Time: 3-5days after confirm order
Payment Terms: T/T,Paypal,L/C,
Supply Ability: 1500
Detailed Product Description
Output Signal: 4-20mA/HART Power Supply: 24V DC
Operating Temperature: -40 To +140C Skype: Summer.cao39
Name: Differential Pressure Transmitter

4-20 mA differential pressure transmitter with HART protocol

 

4-20 mA differential pressure transmitter with HART protocol

 

 

Function Parameters:                                                                                                     

1. Applicable Object: Liquid, gas, steam

2. Measuring range: 0~0.1KPa to 0~40MPa

3. Output Signal: 4~20mA DC

4. Power Source: 12~45V DC, 24V DC on average

5. Load Characteristic: Depend on power resource. The relation of RL and VS is: RL≤50 (VS-12)

6. Indicating Gauge: Multiple parameters and multiple ways LCD indicate header

7. EX-proof:   a. Exd Type ExdllCT6     b. intrinsic safety Type ExidllCT4

8. Range and Zero Point: Outer continually adjustable

9. Positive And Negative Shift: When zero passes positive or negative shift, upper limit and lower limit of

measuring range cannot exceed 100% of upper limit. The maximum positive shift is 500% that of minimum

adjustment range; the maximum negative shift range is 600% that of minimum adjustment range.

10. Temp Range: Working temperature range of amplifier: -29~+93 °c (LT type: -25~+70°c)

11. Filling silicone oil measuring element: -40~+104°C

12. Filling High Temperature Oil to Flange Transmitter : +15~+315°C

13. Common Silicone Oil: -40~+149°C

14. Static Pressure: 4, 10, 25, 32MPa

15. Humidity: relative humidity 0~100%

16. Volume Absorb Quantity: <0.16cm3

Hot sales LCD display HART protocol differential pressure transmitter  .jpg

 

 

Differential Pressure Transmitter MainTechnical Parameters:                                 

 

Accuracy: 

±0.1%, ±0.075%

Dead zone: 

No (≤0.1%)

Stability: 

Less than the absolute value of basic error of maximum range

 within 6 months.

Vibration Effect:

 With 200HZ vibration frequency and error that of ±0.05%/g upper 

limit of measuring  range in arbitrary axis 

Power Source Effect:

 <0.005%/V output range 

Load Effect: 

No load effect under stable power source

 

Capacitance LCD display 3051DP pressure transmitter made in China .jpg

 

                          Ording information sheet                             

 

Type

Directions

 

AT1151DP

 

Differential Pressure Transmitter

 

Measuring

Span

4

 

 

 

 

0~6.2~37.4kPa

 

5

 

 

 

 

0~31~186.8kPa

6

 

 

 

 

0~117~690kPa

 

7

 

 

 

 

0~345~2068kPa

8

 

 

 

 

0~1170~6890kPa

Output signal

 

E

 

 

 

4~20mA   DC

 

 

S

 

 

 

4~20mA  DC two-wire  +HART protocol

 

Wetted Parts

Material

 

 

 

 

 

Flange/Joint 

Exhaust/DrainValve

Diaphragm

Filled liquid

 

 

 

22

 

 

316L SS

316L SS

316L SS

Silicone oil

 

 

 

23

 

 

316L SS

316L SS

 Hastelloy C

Silicone oil

 

 

 

24

 

 

316L SS

316L SS

Monel

Silicone oil

 

 

25

 

 

316L SS

316L SS

Tantalum

Silicone oil

 

 

56

 

 

 Hastelloy C

 Hastelloy C-276

Hastelloy C-276

Silicone oil

Option

 

 

 

M1

 

Linear Instruction Header  (0~100% scale)

 

 

 

 

M2

 

Squar e Root Instruction Header(0~100% scale)

 

 

 

M3

 

Four-digit LCD Header(0~100% linear  display)

 

 

 

 

M4

 

Four-digit LCD Header  (can be specifically set )

 

 

 

B1

 

Tube-type Curved Bracket (Tube ODΦ50~Φ60)

 

 

 

 

B2

 

Board- type Curved Bracket 

 

 

 

B3

 

Tube-type Straight Bracket (Tube ODΦ50~Φ60) 

 

 

 

D1

 

Flange side vent/drain valve at the top

 

 

 

 

D2

 

The flange side vent/drain valve at the bottom

 

 

 

J

 

D-shaped” Joint with “ M20*1.5” External thread

 

 

 

 

N

 

“Kidney-shaped” Joint with 1/2-14NPT 

 

 

 

C12

 

Cited Pressure Transition Joint with 1/2-14NPT, 

and Stainless Steel Cited Pressure Pipe Welding in 

the Rear 

 

Explosion-proof requirements

 

 

 

 

--

Standard (no explosion)

 

 

 

 

 

D

explosion-proof:Exd II BT 5

 

 

 

 

 

i

The Ann model:Exia II CT 6

 

Capacitance LCD display 3051DP pressure transmitter made in China1.jpg

 

Factory workshop:                                                                                                    

 

4-20 mA differential pressure transmitter with HART protocol

4-20 mA differential pressure transmitter with HART protocol

 

4-20 mA differential pressure transmitter with HART protocol

 

4-20 mA differential pressure transmitter with HART protocol

 

Installation:

installation.jpg

 

installation method.jpg

 

4-20 mA differential pressure transmitter with HART protocol

Package:

.jpg

 

4-20 mA differential pressure transmitter with HART protocol

 

4-20 mA differential pressure transmitter with HART protocol

 

4-20 mA differential pressure transmitter with HART protocol

 

 

 

Contact me:

 

4-20 mA differential pressure transmitter with HART protocol

Contact Details
Yantai Auto Instrument Making Co.,Ltd

Contact Person: Ms. Summer

Tel: 86--13145357370

Send your inquiry directly to us (0 / 3000)