Product Details:
Payment & Shipping Terms:
|
Output Signal: | 4-20mA+HART | Accuracy: | 0.1% |
---|---|---|---|
Communication: | HART | Product Name: | Digital Pressure Transmitter |
Power Supply: | 24VDC | Process Connection: | 1/2-14NPT |
Skype: | Summer.cao39 |
3051DPT DP GP AP digital pressure transmitter
3051DP differential pressure transmitter is used for the level,density and pressure measurement of liquid,
gas or vapor,then transfer into 4-20mA DC signal output.
3051 DP is avaialbe to connect with HART communication to display,record,control,monitor data.
Features:
1.real-time to revise meter configuration in meter process:ex.adjust range(span),monitored variable etc.
2.intelligent linear process pressure signal,insure reliability and accuracy of the measuring data on the circuit
board there is reverse protect circuit , current foldback circuit,avoid circuit accidental damage.
3.parameter store in E²PROM after configuration,remain unchanged
4.high accuracy and reliability
5.solid-state element,plug type electronic circuit board,anti-vibration
6.anti-explosion structure,all-weather use
3051DPT DP GP AP digital pressure transmitter
Process fluid: liquid,gas,vapor |
Display:4 digits programmable&0-100%bargraph |
Application:differential pressure,gauge pressure, absolute pressure |
Measuring range:0~0.125kPa~1.5kPa(minimum),0~4.0kPa~25.0kPa(maximum) |
Turn down ration:1:100 |
Accuracy:±0.075% of span |
Stability:±0.15% of URL 2 years |
Working temperature:-25 to 950C |
Display unit:standard 22 engineer unit,4 digits programmable for special unit |
Keyboard:3 keys from internal for programming and outout setting |
Current output:4-20mA 2 wires Hart Protocol ,Rohm=(Vdc-9)*50 |
Power supply:9-36VDC |
Damping adjustment:0-32 second |
Max pressure:40MPa |
Respond time:200ms |
Mounting:bracket on 2” pipe |
Humidity limits:0 to 100% relative humidity |
Turn on time:2 seconds with minmum damping |
Zero calibration:automatic zero calibration by press button |
Electrical connections:1/4”NPT (M20 Conduit threads) |
Temperature effect:±0.18% of span per 200C |
Vibration effect:±0.05% of URL per g to 200 Hz in any axis |
EMI/RFI effect:follow SAMA PMC 33.1 from 20 to 1000MHz and for field strengths up to 30V/m |
Process connections:1/4-18NPT, 1/2-14NPT(with adapter) |
Ambient temperature:-25 to 800C |
Dimension:102mm(W)*188mm(H)*130mm(D) |
Weight:5.5kg |
3051DPT DP GP AP digital pressure transmitter
Material:
Flange /Adapters:stainless steel 304/316 |
Drains/Vents:stainless steel 304/316 |
Diaphragms:stainless steel 316L/Hastelloy B/Hastelloy C/Monel/Tantalum |
Wetted O-Rings: Buna N/Viton/PTFE |
Bolts&nuts:carbon steel/stainless steel 316 |
Mounting Bracket:carbon steel/stainless steel 304/316 |
Name/Tag plate:stainless steel 304/316 |
Converter housing:low copper cast aluminum alloy with polyurethane, light blue paint |
Fill fluid:silicone/fluorine oil |
Enclosure:IP65 |
Intrinsically safe:ia II C T6 |
Explosion proof: d II B T5Absolute pressure sensor transmitter for natual gas |
Order sheet:
Model | Spec Code | Directions | ||
AT3051DP | ……………… | Smart Pressure Transmit ter | ||
Measuring range
|
3…………… | 1.3~7.5 kPa | ||
4…………… | 6.2~37.4 kPa | |||
5…………… | 31~186.8 kPa | |||
6…………… | 117~690 kPa | |||
7…………… | 345~2068 kPa | |||
8…………… | 1170~6890 kPa | |||
Output signal | E…………… | 4~20mA | ||
S…………… | 4~20mA, HART Protocol DigitalCommunication | |||
L…………… | 4~20mA, Smart Field Adjustable | |||
Wetted parts material | Flange/Joint | Exhaust/DrainValve | Diaphragm | |
22…………… |
316stainless steel |
316stainless steel |
316stainless steel | |
23…………… | hasteslloyC-276 | |||
24…………… | Monel | |||
25…………… | Tantalum | |||
56…………… | Hastelloy C | Hastelloy C-276 | Hastelloy C-276 | |
Flange joint | J…………… | “D- shaped” Joint with “M20*1.5” External thread | ||
N…………… | “ Kidney-shaped” Joint with 1/2-14NPT | |||
C12…………… |
Cited Pressure Transition Joint with 1/2-14NPT, and Stainless Steel Cited Pressure Pipe Welding in the Rear |
|||
Mounting bracket | B1…………… | Tube-type Curved Bracket (Tube ODΦ50~Φ60) | ||
B2…………… | Board-type Curved Bracket | |||
B3…………… | Tube-type Straight Bracket (Tube ODΦ50~Φ60) | |||
Display header(optional) | M1…………… | Linear Instruction Header (0~100% scale) | ||
M2…………… | Square Root Instruction Header (0~100% scale) | |||
M3…………… | Four- digit LCD Header(0~100% linear display) | |||
M4…………… | Four- digit LCD Header (can be specifically set ) | |||
Process flange | D…………… | Exhaust or Drain in the Rear | ||
Special Specification |
d…………… | Explosion-proof License: d Ⅱ B T5 | ||
i…………… | Intrinsically Safe Approval: ia Ⅱ C T6 | |||
Typical Model |
AT3051DP4S22M3B1DJ
|
3051DPT DP GP AP digital pressure transmitter