Product Details:
Payment & Shipping Terms:
|
Current Output: | 4-20mA,4-20mA+HART,RS485,1~5V | Accuracy: | 0.075%F.S Or 0.5%F.S |
---|---|---|---|
Flange: | DN50 DN80 DN100 | Power Supply: | 9-36V DC |
Electric Interface: | 1/2NPT OR M20*1.5 | Working Temperature: | -25 To +240 C |
flange mounted level transmitter of manufacture
Product Description
3051LT level transmitter used to measure liquids containing solids and sediment level and density, and then transformed into 4-20mADC signal output. 3051LT can communicate with each other with a HART Communicator, through their set, monitor and so on.
Technical Parameter
Max ref accuracy:±0.075%calibration range
Stability:6months,±0.1%URL
Static pressure:13.79Mpa
Isolation diaphragm:316Lstainlesssteel,HC,Monel,tantalum
stability:6months,±0.1%URL
Damping time constant:time constant is adjustable, in 0.1 second increments from a minimum to 16 seconds
Application: Petrochemical, Chemical, Power, Steel, Cement
Order sheet
Name |
Specification code |
Explanation |
||
3051LT |
|
Level transmitter |
||
|
4 |
635-3810 mmH2O |
||
5 |
3175-19090 mmH2O |
|||
6 |
11730-70380 mmH2O |
|||
Output Signal |
E |
4-20mA |
||
S |
4-20mA, HART Protocol Communication |
|||
Installation flange |
H5 |
2” (DN50) |
||
A8 |
3”(DN80) |
|||
B10 |
4”(DN100) |
|||
Wetted Parts Material |
|
Flange/Joint |
Exhaust/Drain Valve |
Diaphragm |
22 |
Stainless Steel |
Stainless Steel |
316L Stainless Steel |
|
23 |
Hastelloy C-276 |
|||
24 |
Tantalum |
|||
Display Header (optional) |
M2 |
Linear Pointer Header (0~100% scale) |
||
M3 |
Square Root Instruction Header(0~100% scale) |
|||
M4 |
LCD Header( linear display) |
|||
Process Flange |
D1 |
The liquid discharge / exhaust at the side top |
||
D2 |
The liquid discharge / exhaust at the side bottom |
Contact